The short circuit on any DC output shall not cause any
damage to the power supply, including the primary fuse.
¡¡
GENERAL SPECIFICATIONS ¡¡
¢«Hold-up time:
18ms at 115Vac/60Hz,
18ms at 230Vac/50Hz.
¢«Efficiency:
65% min. 115Vac at full load
¢«MTBF:
100,000 hours at full load at 25¡É
¢«Power good signal:
100ms to 500 ms
¡¡
ENVIRONMENTAL SPECIFICATIONS
¢«Operating temperature:
0¡É to +50¡É
¢«Storage temperature:
-20¡É to +80¡É
¢«Relative humidity:
5% to 95% RH non-condensing
¡¡
OutPut
¡¡
Output Voltage
Min. load
Max. load
Load Reg.
Ripple & Noise
+5Vsb
0.0A
2.0A
+5%-4%
50mV P-P
-5V
0.0A
0.3A
¡¾10%
120mV P-P
-12V
0.0A
0.8A
+9%-5%
120mV P-P
+12V3
0.5A
8.0A
+5%-4%
120mV P-P
+12V2
0.5A
12.0A
+5%-4%
120mV P-P
+12V1
1.0A
16.5A
+5%-4%
120mV P-P
+5V
0.5A
30.0A
+5%-4%
50mV P-P
+3.3V
0.5A
30.0A
+5%-4%
50mV P-P
‧+3.3V & +5V total output shall not exceed 200 W.
‧-5V &-12V total output shall not exceed 10 W.
‧+3.3 V &+5V & +12V total output shall not exceed 440W.