FSP350-50BR2
New Page 1
Output Voltage
Min. load
Max. load
Load Reg.
Ripple & Noise
+5Vsb
0.0A
2.5A
¡¾5%
50mV P-P
-12V
0.0A
0.8A
¡¾10%
150mV P-P
+12V
1.0A
15.0A
¡¾5%
120mV P-P
+3.3V
0.3A
28.0A
¡¾5%
50mV P-P
+5V
1.5A
30.0A
¡¾5%
50mV P-P
Safety
Features
¡¡
High efficiency
Low Ripple & Noise
Output over voltage protection
Short circuit protection on all outputs
Resetable power shut down
100% burn-in under high ambient temperature(50¡É)
Vacuum-impregnated transformer
MTBF:100K hours at 25¡É
100% Hi-pot tested
Line input fuse protection
Specifications
¡¡
¡¡
INPUT SPECIFICATIONS
¡¡
¢«Input voltage:
Full Range Input
¢«Input frequency:
47 Hz to 63 Hz
¢«Inrush current:
70Amps-peak/115Vac
120Amps-peak/230Vac
¢«Input current:
7.0Amps/115Vac
3.5Amps/230Vac
¡¡
OUTPUT SPECIFICATIONS
¡¡
¢«Over voltage protection:
+12V output: 14.5V max;
+5V output: 6.5V max..;
+3.3V output: 4.5V max;
¢«Over current protection:
+5V: 240VA max;
+3.3V: 240VA max;
+12V: 240VA max.
¢«Short circuit protection:
The short circuit on any DC output shall not cause any damage to the power supply, including the primary fuse.
¡¡
GENERAL SPECIFICATIONS
¢«Hold-up time:
20ms
¢«Efficiency:
65% typical at full load and 115Vac input.
¢«MTBF:
100,000 hours at full load at 25¡É
¢«Power good signal:
50ms to 500 ms
¡¡
ENVIRONMENTAL SPECIFICATIONS
¢«Operating temperature:
+5¡É to +40¡É
¢«Non-Operating temperature:
-10¡É to +50¡É
¢«Relative humidity:
Operating:20 to 90% non-condensing at 40¡É
Non-Operating:5 to 95% non-condensing at 50¡É
¡¡
¡¡
OutPut
¡¡
Output Voltage
Min. load
Max. load
Load Reg.
Ripple & Noise
+5Vsb
0.0A
2.5A
¡¾5%
50mV P-P
-12V
0.0A
0.8A
¡¾10%
150mV P-P
+12V
1.0A
15.0A
¡¾5%
120mV P-P
+3.3V
0.3A
28.0A
¡¾5%
50mV P-P
+5V
1.5A
30.0A
¡¾5%
50mV P-P
‧+3.3V & +5V total output shall not exceed 157 W.
‧+3.3 V &+5V & +12V total output shall not exceed 330W.