FSP300-602U
New Page 2
Output Voltage Min. load Max. load Load Reg. Ripple & Noise
+5Vsb 0.0A 2.0A ¡¾5% 100mV P-P
-5V 0.0A 0.3A ¡¾5% 100mV P-P
-12V 0.0A 0.8A ¡¾10% 120mV P-P
+12V 1.0A 20.0A ¡¾5% 120mV P-P
+5V 2.0A 25.0A ¡¾5% 50mV P-P
+3.3V 0.3A 20.0A ¡¾5% 50mV P-P

¡¤ Å©±â : 220 x 84 x 83 mm
¡¤ Àû¿ë±â±â : For Server & Workstation
¡¤ Watt : 300
¡¤ PFC : Active PFC
¡¤ Äð¸µÆÒ : 80mm
¡¤ Drawing :
Drawing

 FSP300-602U Ãâ½ÃÀÏ : 2007-05-25 14:53:23

Safety
Features
¡¡
  • High efficiency
  • Low Ripple & Noise
  • Output over voltage protection
  • Short circuit protection on all outputs
  • Resettable power shut down
  • INTERNAL 8 cm fan
  • 100% burn-in under high ambient temperature(50¡É)
  • Vacuum-impregnated transformer
  • MTBF:100K hours at 25¡É
  • 100% Hi-pot tested
  • line input fuse protection
  • complies with EN61000-3-2
  • AC input full range
Specifications
¡¡ ¡¡
  • mote ON/OFF Control:   The power supply shall accept a logic collector
                                               level which will disable / enable all output voltage
                                               (excluding +5V standby).
  • Temperature range:            operating 0 ~ 50 ¡É, 
                                               storage -20 ~ +80 ¡É
  • Temperature coefficient:     0.01% / ¡É
  • Transient response:             output voltage recovers in less than 1 ms max.
                                               following a 25% load change
  • Hold-up time:                      17ms minimum at full load
  • Dielectric withstand:            input/output 1800 VAC for 1 second,
                                                input to frame ground 1800VAC for 1 second
  • Humidity:                             5~95% RH
  • Efficiency:                            68% min., at full load
  • Power good signal:                turn-on delay 100 ms to 500 ms
  • Overload protection:            150% max.
  • Inrush current:                    60A cold , 90A ware at 132 VAC
  • Over voltage protection:      +5V output : 6.82V max. 
                                               +3.3V output: 4.5V max.
  • Voltage:                               100-240 VAC full range
  • Frequency:                           47 Hz tO 63 Hz
  • Input current:                      6 amps maximum/115V,60 Hz. 
                                                3 amps maximum/230V,50Hz 

OutPut
¡¡
Output Voltage Min. load Max. load Load Reg. Ripple & Noise
+5Vsb 0.0A 2.0A ¡¾5% 100mV P-P
-5V 0.0A 0.3A ¡¾5% 120mV P-P
-12V 0.0A 0.8A ¡¾5% 120mV P-P
+12V 0.2A 15.0A ¡¾5% 120mV P-P
+5V 2.0A 30.0A ¡¾5% 50mV P-P
+3.3v 0.3A 20.0A ¡¾5% 50mV P-P

¡¡‧+3.3V &+5V total output not exceed 160W
‧+3.3V & +5V & +12V total output not exceed 280W