FSP350-601U
New Page 2
Output Voltage Min. load Max. load Load Reg. Ripple & Noise
+5Vsb 0.0A 2.0A ¡¾5% 100mV P-P
-5V 0.0A 0.3A ¡¾5% 100mV P-P
-12V 0.0A 0.8A ¡¾10% 120mV P-P
+12V 1.0A 20.0A ¡¾5% 120mV P-P
+5V 2.0A 25.0A ¡¾5% 50mV P-P
+3.3V 0.3A 20.0A ¡¾5% 50mV P-P

¡¤ Å©±â : 220 x 100 x 40.5 mm
¡¤ Àû¿ë±â±â : For Server & Workstation
¡¤ Watt : 350
¡¤ PFC : Active PFC
¡¤ Äð¸µÆÒ : 40mmÆÒ
¡¤ Drawing :
Drawing

 FSP350-601U Ãâ½ÃÀÏ : 2007-05-25 14:43:31

Safety
Features
¡¡
  • High efficiency
  • Low Ripple & Noise
  • Output over voltage protection
  • Short circuit protection on all outputs
  • Resettable power shut down
  • INTERNAL 4 cm fan x 2
  • 100% burn-in under high ambient temperature(50¡É)
  • Vacuum-impregnated transformer
  • MTBF:100K hours at 25¡É
  • 100% Hi-pot tested
  • line input fuse protection
  • Complies with EN61000-3-2
  • AC input full range
Specifications
¡¡
  • Remote ON/OFF Control:   The power supply shall accept a logic collector
                                               level which will disable / enable all output voltage
                                               (excluding +5V standby).
  • Temperature range:            operating 0 ~ 50 Deg.C,
                                               storage -20 ~ +80 Deg.C
  • Temperature coefficient:     0.01% / Deg.C
  • Transient response:             output voltage recovers in less than 1 ms max. 
                                               following a 25% load change
  • Hold-up time:                      17ms minimum at full load
  • Dielectric withstand:           input/output 1800 VAC for 1 second,
                                               input to frame ground 1800VAC for 1 second
  • Humidity:                           5~95% RH
  • Efficiency:                          65% min., at full load
  • Power good signal:              turn-on delay 100 ms to 500 ms
  • Overload protection:          150% max.
  • Inrush current:                  60A cold, 90A ware at 132 Vac
  • Over voltage protection:    +5V output : 6.82V max. 
                                             +3.3V output: 4.5V max.
                                             +12V output: 15.6V max. 
  • Voltage:                           100-240 VAC full range
  • Frequency:                       47 Hz tO 63 Hz
  • Input current:                  6 amps maximum/115V,60 Hz.
                                            3 amps maximum/230V,50Hz 

OutPut
¡¡
Output Voltage Min. load Max. load Load Reg. Ripple & Noise
+5Vsb 0.0A 2.0A ¡¾5% 100mV P-P
-5V 0.0A 0.3A ¡¾5% 100mV P-P
-12V 0.0A 0.8A ¡¾10% 120mV P-P
+12V 1.0A 20.0A ¡¾5% 120mV P-P
+5V 2.0A 25.0A ¡¾5% 50mV P-P
+3.3V 0.3A 20.0A ¡¾5% 50mV P-P

‧+3.3V &+5V total output not exceed 157W
‧+3.3V & +5V & +12V total output not exceed 330W