Safety |
|
|
|
|
 |
Features |
|
| ¡¡ |
- High efficiency
- Low Ripple & Noise
- Output over voltage protection
- Short circuit protection on all outputs
- Resetable power shut down
- Low Noise Design at full load
- 100% burn-in under high ambient temperature(50¡ÆC)
- Vacuum-impregnated transformer
- MTBF:100K hours at 25¡ÆC
- 100% Hi-pot tested
- Line input fuse protection
|
|
 |
Specifications |
|
| ¡¡ |
| INPUT SPECIFICATIONS |
¡¡ |
| ¢«Input voltage: |
100-120 / 200-240VAC |
| ¢«Input frequency: |
47 Hz to 63 Hz |
| ¢«Inrush current: |
shall be limited to 42 amps cold,70amps warm measured at 132
Vrms, 60Hz and coinciding with the AC main voltage peak. |
| ¢«Input current: |
8 amps maximum / 115 Vrms, 60Hz;
4 amps maximum / 230 Vrms, 50Hz. |
¡¡
| OUTPUT SPECIFICATIONS¡¡ |
| ¢«Over voltage protection: |
+12V output:15.5V max;
+5V output: 6.5V max;
+3.3V output: 4.6V max. |
| ¢«Overload protection: |
+5V: 60Amps;
+3.3V: 58Amps;
+12V: 22Amps; |
| ¢«Short circuit protection: |
The short circuit on any DC output shall not cause any
damage to the power supply, including the primary fuse. |
¡¡
| GENERAL SPECIFICATIONS ¡¡ |
| ¢«Hold-up time: |
16.6ms at 115Vac/60Hz(normal load),
20.0ms at 230Vac/50Hz(normal load). |
| ¢«Efficiency: |
65% min. |
| ¢«MTBF: |
100,000 hours at full load at 25¡É |
| ¢«Power good signal: |
115V / 230V (FULL LOAD) : 100-500mS |
¡¡
ENVIRONMENTAL SPECIFICATIONS
| ¢«Operating temperature: |
0¡É to +50¡É |
| ¢«Storage temperature: |
-20¡É to +65¡É |
| ¢«Relative humidity: |
Operating: 90%
Storage:95% |
¡¡¡¡ |
|
 |
OutPut |
|
|
¡¡
|
Output Voltage |
Min. load |
Max. load
|
Load Reg. |
Ripple & Noise |
| +5Vsb |
0.0A |
2.0A |
+5% |
50mV P-P |
| -5V |
0.0A |
0.3A |
+10% |
120mV P-P |
| -12V |
0.0A |
0.8A |
+10% |
120mV P-P |
| +12V |
0.0A |
10A |
+5% |
120mV P-P |
| +5V |
1.5A |
30/23A |
+5% |
50mV P-P |
| +3.3V |
0.2A |
3/14A |
+5% |
50mV P-P |
‧+3.3V &+5V total output not exceed 160W
‧+3.3V & +5V & +12V total output not exceed 280W |
|
|
|